Welcome toA clothing company

When selecting a flow meter for corrosive liquids, how should the material be chosen? 316L or PTFE?

2026-09-18 10:48:27
views
Reading time: about 5 minutes

Q:When measuring corrosive liquids, how should the wetted material of the flow meter be selected? Which one should I choose between 316L stainless steel and PTFE polytetrafluoroethylene?

A:316L stainless steel and PTFE are the two most commonly used wetted materials for measuring the flow of corrosive liquids, but theyare suitable for completely different corrosive scenarios.In short:316L stainless steelResistant to weakly corrosive acids, alkalis, and salt solutions. It is economical and versatile, suitable for low-concentration weak acids, organic acids, and alkaline solutions at room temperature.PTFE PolytetrafluoroethyleneResistant to strong acids, strong alkalis, and almost all organic solvents, it is the preferred choice for highly corrosive media, but its resistance to temperature and pressure is limited, and it is not resistant to negative pressure. When selecting a model, you cannot simply ask "which one is better"; instead, you shouldmake a comprehensive assessment based on the type of medium, its concentration, temperature, and pressure.Below, we systematically compare the two materials from several perspectives to help you make the right choice.

I. Comparison of Core Properties Between 316L and PTFE

Comparison criteria316L Stainless SteelPTFE Polytetrafluoroethylene
Corrosion resistanceResistant to weakly corrosive acids, alkalis, and salt solutions, with some resistance to chloride ionsResistant to strong acids, strong alkalis, oxidizing agents, and almost all organic solvents, with extremely high chemical stability
Applicable mediaDomestic/industrial water, sewage, weak acidic and alkaline salt solutions, concentrated nitric acid at room temperature, organic acids (low concentration at room temperature)The vast majority of corrosive media, such as hydrochloric acid, sulfuric acid, nitric acid, sodium hydroxide, organic solvents, and strong oxidants
Inapplicable mediaStrongly corrosive media such as hydrofluoric acid, hydrochloric acid, chlorine, bromine, and iodineMolten alkali metals, fluorine gas under high temperature and high pressure, some halogenated compounds
Temperature resistance range-196~500°C (depending on operating conditions)-40~180°C (typical), some models can reach 260°C
Pressure resistanceHigh, up to 40 MPa or moreLimited by the lining structure, typically PN16~PN40, and not resistant to negative pressure
Mechanical strengthHigh, good rigidity, wear-resistantLower, softer texture, poor wear resistance
CostLower, economical and versatileHigher, the lining process increases costs

2. Select the material based on the type of medium

When making an actual selection, the most straightforward method is toMatch the material according to the type of mediumThe table below provides selection recommendations based on common types of corrosive media:

Medium TypeRecommended MaterialReason
Weak acids (acetic acid, formic acid, citric acid, low concentration at room temperature)316L stainless steel316L has sufficient corrosion resistance and good cost-effectiveness at room temperature and low concentrations
Strong acids (hydrochloric acid, sulfuric acid, nitric acid)PTFE (or Hastelloy)316L has poor corrosion resistance to reducing acids such as hydrochloric acid and sulfuric acid, while PTFE can resist most strong acids.
Strong bases (sodium hydroxide, potassium hydroxide)PTFE or 316L (low temperature, low concentration)Stainless steel may experience stress corrosion cracking under high-temperature, strong alkaline conditions; PTFE is safer.
Media containing chloride ions (seawater, brine)PTFE (or duplex steel, titanium)316L has limited resistance to chloride ions and may be subject to pitting corrosion at high concentrations or high temperatures.
Organic solvents (aromatic hydrocarbons, alcohols, ketones)316L is generally suitable, but PTFE is safer.Most organic solvents have low corrosivity to stainless steel, but attention should be paid to the compatibility of sealing materials.
Mixed acid-base solutions or media with complex compositionsPTFEWhen the composition is complex, it is difficult to predict the corrosion behavior of 316L, while PTFE is more reliable due to its broad-spectrum corrosion resistance.

III. Key parameters that must be confirmed when selecting a model

Medium name and concentration
Specific chemical name and concentration percentage. The corrosivity varies greatly with different concentrations. For example, the corrosive behavior of sulfuric acid is completely different at low and high concentrations.
Operating temperature
An increase in temperature significantly accelerates corrosion. The corrosion resistance of 316L decreases significantly at high temperatures, and PTFE will also soften and deform above 180°C.
Operating pressure
PTFE lining has limited pressure resistance and is not resistant to negative pressure. For high-pressure operating conditions, metal materials such as 316L or Hastelloy are preferred.
Presence of chloride ions
Chloride ions can cause pitting and crevice corrosion in stainless steel. 316L may fail in environments with high concentrations of chloride ions or high temperatures, so PTFE or titanium should be considered.
Presence of particles
PTFE has poor wear resistance, and media containing solid particles will accelerate the wear of the lining. Its suitability needs to be assessed.
Is negative pressure possible?
Under negative pressure conditions, the PTFE lining may contract and deform inward, leading to measurement errors or even damage to the lining. This requires special verification.

The following information must be confirmed before selecting corrosive liquids:

  • Medium name and concentration:Specific chemical name, concentration percentage, and whether it is a mixed medium.

  • Operating temperature:Normal temperature and maximum temperature. Temperature has a significant impact on the corrosion rate.

  • Operating pressure:System pressure, whether negative pressure is possible.

  • Chloride ion content:Whether it contains chloride ions and the concentration level determine whether to exclude 316L.

  • Solids content and particles:Whether it contains solid particles and whether it is prone to crystallization.

  • Seal compatibility:Whether the material of the sealing ring and O-ring is compatible with the medium (e.g., PTFE-coated, FFKM, etc.).

  • Accuracy and signal:Accuracy requirements, output signal type, and whether explosion-proof or sanitary grade is required.

IV. GN Instruments Corrosive Liquid flow meter Solution

For corrosive liquid applications,GN Instruments Instrument Co., Ltd.The following wetted material options are available:

Material OptionsApplicable MediaTemperature/PressureFeatures
316L stainless steelWeakly corrosive acid, alkali, and salt solutions, neutral chemical solutions, organic solventsHigh temperature resistance, pressure resistance up to 40 MPaEconomical and versatile, high strength, wear-resistant
PPS engineering plasticStrong acids, strong bases, most organic solventsLower temperature and pressure resistance than metalGood chemical stability and moderate cost
PTFE liningThe vast majority of corrosive media, such as strong acids, strong bases, oxidizing agents, and organic solvents-40~180°C, pressure resistance PN16~PN40Broad-spectrum corrosion resistance, low coefficient of friction, suitable for highly corrosive media
HastelloyStrongly reducing acids such as hydrochloric acid and sulfuric acid, mixed acidsHigh temperature and pressure resistanceHigh-strength corrosion resistance, suitable for high-temperature, high-pressure, and highly corrosive operating conditions

Our engineers will recommend a suitable wetted material solution based on parameters such as the name of your fluid, its concentration, temperature, pressure, and chloride ion content. For media whose suitability is uncertain, it is recommended to provide detailed operating condition information for engineers to conduct a material compatibility assessment. If necessary, prototype testing can be arranged to verify corrosion resistance and metering accuracy under actual operating conditions.