Welcome toA clothing company

What are the measurement ranges of different vacuum gauges? How do I match a vacuum system?

2026-09-20 11:02:15
views
Reading time: about 5 minutes

Q:What are the measurement ranges of different vacuum gauges? How do I match them to a vacuum system?

A:The measurement ranges of different vacuum gauges vary greatly.There is no single vacuum gauge that can cover the entire range from atmospheric pressure to ultra-high vacuum.Therefore, the core principle for matching a vacuum system is"Segment by pressure and use in combination."Capacitance diaphragm gauges are suitable for precision measurements in low vacuum, Pirani gauges are suitable for economical monitoring in rough and low vacuum, cold cathode and hot cathode ionization gauges are suitable for high vacuum and ultra-high vacuum, and compound gauges cover a wide range. When matching, first determine the operating pressure range of the system, then consider the type of gas and accuracy requirements, and finally select a single or combined solution. GN Instruments offers a full range of vacuum gauge products, including Pirani resistance vacuum gauges, compound vacuum gauges, capacitance diaphragm vacuum gauges, and vacuum gauge controllers. We can recommend suitable configurations based on the operating conditions of the vacuum system.

I. Overview of the Measuring Ranges of Various Types of Vacuum Gauges

The table below summarizes the types, principles, and measurement ranges of mainstream vacuum gauges for quick reference:

Vacuum Gauge TypeMeasurement PrincipleTypical Measurement Range (Pa)Key Features
Capacitance Diaphragm Gauge (CDG)Direct measurement: The diaphragm deforms under pressure, and the pressure is measured through changes in capacitance.0.1 ~ 1×10⁵ Pa (up to 0.01 Pa)Regardless of the type of gas, it has high accuracy (up to ±0.5% FS) and is the preferred choice for precision measurements in the low vacuum range.
Pirani Vacuum GaugeIndirect measurement: Uses gas thermal conduction to calculate pressure based on changes in the resistance of the heating filament.0.01 ~ 150,000 PaLow cost, wide range of applications, readings are greatly affected by the type of gas, and calibration is required according to the gas.
cold cathode ionization vacuum gaugeIndirect measurement: Uses cold cathode discharge to generate an ion current, and measures pressure through the discharge current.1×10⁻¹ ~ 1×10⁻⁸ PaRobust construction, long service life, wide measurement range, relatively low accuracy
hot cathode ionization vacuum gaugeIndirect measurement: Uses electrons emitted by a hot cathode to ionize gas, and measures pressure through ion current.1×10⁻¹ ~ 1×10⁻¹⁰ PaMost commonly used for high vacuum/ultra-high vacuum, high precision, fragile filament, not resistant to contamination
Composite vacuum gaugeCombination type: Pirani and ionization gauge (cold/hot cathode) integrated into one unit1×10⁵ ~ 1×10⁻⁵ Pa (or wider)A single gauge covers a wide range, providing continuous measurement from rough vacuum to high vacuum, simplifying system configuration.

Unit Conversion Reference:

1 mbar ≈ 100 Pa, 1 Torr ≈ 133 Pa. The specific model ranges may vary among different manufacturers. The table above provides general reference ranges.

2. How to match a vacuum gauge to a vacuum system?

The core logic of matching is:First, determine the system's operating pressure range, then consider the gas type and accuracy requirements, and finally choose a single or combined solution.。

Step 1: Match by pressure range (most critical)

Based on the process vacuum level, select directly from the table below:

Vacuum rangePressure Range (Pa)Recommended Vacuum Gauge TypesTypical Application Scenarios
Rough vacuum1×10⁵ ~ 1×10²Capacitance diaphragm vacuum gauge, Pirani vacuum gaugeVacuum drying, vacuum packaging, roughing line monitoring
Medium vacuum1×10² ~ 1×10⁻¹Capacitance diaphragm vacuum gauge, Pirani vacuum gaugeVacuum deposition (low vacuum section), vacuum degassing, lighting
High vacuum1×10⁻¹ ~ 1×10⁻⁵cold cathode/hot cathode ionization gauges, compound vacuum gaugesSemiconductor etching, PVD/CVD, vacuum deposition
Ultra-high vacuum< 1×10⁻⁵hot cathode ionization gauge (B-A gauge), cold cathode ionization gaugeSurface analysis, ALD, particle accelerators

For example, if the process is set at5~6 mTorr (approximately 0.67~0.8 Pa)When high-precision control is required, a capacitance diaphragm gauge is the ideal choice, with an accuracy of up to 0.5% of the full scale.

Step 2: Consider the type of gas

Single or known gas type
Pirani or ionization gauges can be usedAfter calibrationThey are available, cost-effective, and suitable for clean operating conditions with fixed gas types.
Changing gas types, mixed gases, or corrosive gases
Capacitance diaphragm vacuum gauges must be given priority.It directly measures pressure, regardless of the type of gas, without the need for conversion factors, thus avoiding cumbersome gas calibrations and reading errors.

Step 3: Determine a single or combined solution

Narrow pressure range
Simply select a vacuum gauge that matches this range. For example, if you are only working in the rough vacuum range, choose a Pirani gauge or a capacitance diaphragm gauge.
Pressure range spans multiple zones
A "combination solution" must be used.. The simplest way is to directly selecta compound vacuum gauge(e.g., Pirani + ionization gauge combination), which automatically switches internally to achieve continuous measurement over a wide range.

III. Other Key Considerations When Selecting a Model

ConsiderationsDescription
Accuracy and StabilityCapacitance diaphragm gauges have the highest accuracy (up to ±0.5% FS), while ionization gauges can have errors of up to ±70% under high vacuum conditions. Selection should be based on control requirements.
Environmental adaptabilityIn environments with dust or oil vapor, the Pirani gauge port should be installed facing downward to prevent the deposition of contaminants. In corrosive gas environments, a corrosion-resistant type (such as a special diaphragm material or a corrosion-resistant filament) should be selected.
Calibration and MaintenanceIt is recommended to calibrate at least once a year, and to calibrate immediately when replacing parts or if readings are abnormal.

Summary: The essence of matching vacuum gauges is to "let the right tool work in the right pressure range."

Remember this decision-making chain:Determine the pressure range → Confirm the gas type → Select a single or combined solution → Verify accuracy and environmental requirements。

IV. GN Instruments Vacuum Gauge Product Solutions

For different vacuum measurement needs,GN Instruments Instrument Co., Ltd.The following product solutions are available:

Product SeriesTypeMeasurement RangeApplicable Scenarios
CFG-500 Capacitance Diaphragm GaugeCapacitance diaphragm type1~10⁵ PaPrecision measurement of medium and low vacuum, changes in gas types, or corrosive gas environments
CX-PRN Pirani Vacuum GaugePirani type10⁻¹~10⁵ PaRoutine monitoring of rough and low vacuum, with fixed or adjustable gas types
CX-PRN14 cold cathode Compound Vacuum GaugeCombination type (Pirani + cold cathode)10⁻⁵~10⁵ PaWide-range continuous monitoring, PVD/CVD, etching and other semiconductor processes
CX-PRN15 hot cathode Compound Vacuum GaugeComposite (Pirani + hot cathode)10⁻⁵~10⁵ PaHigh vacuum/ultra-high vacuum measurement, ALD, high vacuum deposition

Our engineers will recommend a suitable vacuum gauge type and configuration based on your vacuum system's operating pressure range, gas types, accuracy requirements, and interface conditions. For precision measurements in low vacuum, capacitance diaphragm vacuum gauges are recommended; for continuous monitoring over a wide range, compound vacuum gauges are recommended; for varying gas types or corrosive gases, capacitance diaphragm vacuum gauges are preferred. If necessary, we can provide prototype testing services to verify the measurement performance under actual operating conditions.