Q:Is an oval gear flow meter suitable for measuring hydraulic oil flow?

A:It is very suitable.Hydraulic oil is a typical high-viscosity liquid, with a viscosity typically ranging from 20 to 500 cSt. On the other hand, an oval gear flow meter is a type of positive displacement flow meter, and its measurement principle determines that itis not affected by the viscosity of the medium. The higher the viscosity, the less leakage there is in the gap between the gear and the chamber, and the more accurate the measurement.At the same time, hydraulic systems typically operate at high pressures (from a few MPa to several tens of MPa). Oval gear flowmeters can be designed as high-pressure models, capable of withstanding pressures of over 40 MPa, and are fully capable of accurately measuring hydraulic oil flow rates. However, it should be noted that hydraulic oil has certain requirements for cleanliness. Particulate impurities can cause the gears to jam, and a filter must be installed at the front end. GN Instruments offers products such as the M Series Micro Gear Flow Meter and the High-Pressure Panel-Mounted Gear Flow Meter, with an accuracy of ±0.5%, suitable for measuring low hydraulic oil flow rates under high-pressure conditions.

I. Why are oval gear flowmeters suitable for measuring hydraulic oil?

Unaffected by viscosity
The positive displacement principle directly measures volume, and changes in hydraulic oil viscosity do not affect measurement accuracy. The higher the viscosity, the lower the leakage, and the more stable the accuracy.
High-pressure resistance
Due to the high pressure in hydraulic systems, the oval gear flow meter can be designed as a high-pressure type, capable of withstanding pressures exceeding 40 MPa, making it suitable for direct installation in hydraulic lines.
High accuracy
The standard accuracy is ±0.5%, with high accuracy reaching ±0.2%, and repeatability ranging from ±0.2% to ±0.5%, meeting the precise measurement and proportioning requirements of hydraulic systems.
Strong self-priming capability
The meshing of the gears creates a vacuum for suction, allowing even high-viscosity hydraulic oil to be smoothly drawn in, reducing the likelihood of cavitation and air intake.
Controllable pressure loss
Although positive displacement flowmeters have a certain amount of pressure loss, it accounts for a very small proportion under the high pressure of hydraulic systems, and has a limited impact on system efficiency.
Compact structure
Compact in size and flexible in installation, with virtually no straight pipe section requirements, it is suitable for installation in the confined spaces inside hydraulic equipment.

II. Key Parameters to Confirm When Selecting Hydraulic Oil

Although oval gear flowmeters are suitable for hydraulic oil, the following parameters still need to be confirmed when selecting a model to ensure long-term stable operation:

ParametersDescriptionRecommended Range/Precautions
Flow Rate RangeMinimum flow rate, normal flow rate, maximum flow rateThe recommended operating point should be within 20%–80% of the measurement range to ensure accuracy at low flow rates.
Operating pressureMaximum system operating pressure and pressure fluctuationsSelect a pressure rating with a safety margin of 1.5 to 2 times, and choose a high-pressure plate assembly type
Operating temperatureNormal operating temperature and maximum temperature of hydraulic oilTypically -20°C to 120°C; high temperatures require special materials and clearance design
ViscosityHydraulic oil viscosity at operating temperature (cSt or cP)Oval gear flowmeters are suitable for 1~500,000 cP, and the higher the viscosity, the better the accuracy.
Filtration precisionHydraulic oil cleanliness level, whether it contains particlesA filter must be installed at the front end; a precision of 10 μm or higher is recommended.
MaterialHousing, gears, bearings, seal materialsTypically 316L stainless steel or aluminum; PPS is recommended for corrosive hydraulic oils.
Output signal4-20mA, pulse, RS485, etc.Depending on the control system interface selection, the supply voltage needs to be confirmed.

III. Comparison with other flowmeters: Why are oval gears more suitable?

flow meter TypeSuitability for measuring hydraulic oilReason
Oval Gear flow meterVery suitablePositive displacement type, unaffected by viscosity, resistant to high pressure, and highly accurate
Turbine flow meterNot suitableDifficult to start the impeller at high viscosity, rapid bearing wear, poor accuracy
Electromagnetic flow meterNot suitableHydraulic oil is non-conductive, and electromagnetic principles cannot be used for measurement.
Coriolis mass flow meterSuitable but costlyDirect mass measurement with high accuracy, but large diameters are expensive.
Differential pressure flow meterGeneralHigh pressure loss at high viscosity, poor accuracy at low flow rates, requires long straight pipe sections

The following information must be confirmed before selecting the hydraulic oil:

  • Hydraulic oil grade and viscosity:For example, 46# and 68# anti-wear hydraulic oils, with viscosity values (cSt) at operating temperature.

  • Flow rate range:Minimum flow rate, normal flow rate, maximum flow rate (L/min or mL/min).

  • Operating pressure:Maximum system pressure, pressure fluctuation range, and whether a high-pressure plate assembly is required.

  • Operating temperature:Normal temperature and maximum temperature, whether a high-temperature model is required.

  • Cleanliness requirements:Hydraulic oil cleanliness level (e.g., NAS Class 8), filter configuration.

  • Installation conditions:Pipe diameter, connection method, installation orientation, available space.

  • Output signal:4-20mA, pulse, RS485, supply voltage.

IV. GN Instruments Hydraulic Oil flow meter Solution

For hydraulic oil flow measurement,GN Instruments Instrumentation Co., Ltd.The following product solutions are available:

Product SeriesFlow rate rangePressure Resistance CapacityFeatures
M Series Micro Gear Flow MeterMinimum 0.5 L/minStandard 4MPa, high pressure can be customizedAccuracy ±0.5%, suitable for measuring low flow rates of hydraulic oil
High-Pressure Panel-Mounted Gear flow meterCustomized by modelCustomizable to over 40 MPaHigh-pressure design, suitable for direct installation in high-pressure lines of hydraulic systems
G Series Gear Flow MeterMedium to high flow ratesStandard 4 MPa, high pressure can be customizedSuitable for medium to high flow rate measurements in hydraulic stations, test benches, etc.

Our engineers will recommend a suitable oval gear flow meter model and configuration based on your hydraulic oil grade, viscosity, flow rate range, operating pressure, temperature, and cleanliness requirements. For high-pressure hydraulic systems, we recommend high-pressure panel-mounted gear flowmeters; for measuring very low hydraulic oil flow rates, we recommend the M Series micro-gear flowmeters. If necessary, we can provide prototype testing services to verify measurement accuracy and long-term stability under real hydraulic operating conditions.