Welcome toA clothing company

How to select a gear metering pump for high-temperature operating conditions?

2026-09-18 11:13:02
views
Reading time: about 5 minutes

Q:How should I select a gear metering pump for high-temperature operating conditions? What issues should be considered?

A:High-temperature operating conditions impose far more stringent requirements on gear metering pumps than those at normal temperatures. Ordinary gear pumps may experience the following issues under high-temperature conditions:material softening, thermal expansion seizure, seal failure, and reduced lubrication performanceand other issues, so selection cannot simply be based on normal temperature conditions. The selection of high-temperature gear metering pumps needs to be considered systematically based ontemperature range and speed limits, material temperature resistance, thermal expansion clearance design, sealing solutions, cooling/insulation methods, and drive configurations.six core dimensions. GN Instruments offers the CXG series of high-temperature gear metering pumps, which can operate at temperatures up to 330°C and be cleaned at temperatures up to 450°C. They are suitable for the transfer and metering of high-viscosity, high-temperature media such as high-temperature resins, hot-melt adhesives, asphalt, and polyurethane.

I. Four Major Challenges Posed by High-Temperature Operating Conditions to Gear Metering Pumps

ChallengeDetailed DescriptionConsequences of improper model selection
Thermal expansion causes changes in clearanceMetal components expand at high temperatures, reducing the clearance between the gears and the pump body, which may lead to seizing or increased wear.Pump body seizure, gear wear, loss of metering accuracy
Decreased material strengthThe hardness, wear resistance, and fatigue resistance of conventional materials decrease at high temperatures.Accelerated gear wear, significantly shortened pump life
Seal failureConventional rubber seals age, carbonize, and lose elasticity at high temperaturesMedium leakage, environmental pollution, and even safety incidents
Decreased lubrication performanceAt high temperatures, the viscosity of the medium decreases, the lubrication film becomes thinner, and bearing wear accelerates.Bearing life drops sharply, vibration and noise increase, and the pump body is damaged

II. Six Core Elements for Selecting High-Temperature Gear Metering Pumps

Temperature Range and Speed Limits
Confirm the maximum temperature of the medium and the cleaning temperature. Under high-temperature operating conditions, it is recommended that the rotational speed does not exceed 50 rpm, and for long-term use, it should not exceed 30 rpm. Excessive rotational speed will exacerbate wear and shorten the service life.
Material temperature resistance
The materials of the pump housing, gears, and bearings must be resistant to high temperatures. For high-temperature applications, options include chromium-nickel alloy steel, high-temperature tool steel, CPM tool steel, or titanium-tantalum alloy. After full hardening, the hardness can reach HRC62-68.
Thermal Expansion Clearance Design
High-temperature pumps must have a dedicated thermal expansion clearance, typically 1.2 to 1.5 times the clearance at room temperature. When the medium temperature exceeds 150°C, the pump body must be preheated before startup.
Sealing Solution
Seals are prone to failure at high temperatures. For standard operating conditions, options include fluororubber lip seals, graphite packing seals, and PTFE packing seals. For high-temperature, high-pressure, or corrosive media, metal bellows seals are recommended.
Cooling/Insulation Method
The pump body can be designed with a circulating jacket, through which heat transfer oil, steam, or cooling water can be introduced for heating/insulation/cooling. For high-temperature operating conditions, models with cooling jackets or heat sinks can be selected.
Drive Configuration
For high-temperature operating conditions, it is recommended to use a gearbox with a higher gear ratio to reduce the rotational speed. Servo motors, stepper motors, explosion-proof motors, or brushless motors are available as options, to be selected based on site requirements.

III. Selection Strategies for Different Temperature Ranges

Temperature RangeRecommended SolutionKey Points to Note
≤ 200℃Stainless steel pump body (304/316L), high-temperature resistant sealIf the medium temperature exceeds 90°C, it must be specifically indicated during model selection to ensure seal compatibility.
200~330℃High-temperature special type, chromium-nickel alloy steel or high-temperature tool steelRequires a thermal expansion gap design, preheating before startup, and rotational speed control within 30-50 rpm
330–450°C (including cleaning)CPM tool steel or titanium-tantalum alloy material, special sealRequires specialized high-temperature design, equipped with a cooling system to protect the bearings and seals [reference:10]

IV. List of Parameters to be Confirmed for High-Temperature Selection

The following information must be confirmed before selection:

  • Medium name and temperature:Specific medium name, maximum operating temperature, cleaning temperature, and temperature fluctuation range.

  • Medium properties:Viscosity (at operating temperature), corrosivity, solids content, and whether it is prone to crystallization or vaporization.

  • Flow rate range:Minimum flow rate, normal flow rate, maximum flow rate, and required metering accuracy.

  • Pressure rating:Inlet pressure, outlet pressure, system pressure differential; the pressure rating may need to be derated at high temperatures.

  • Sealing requirements:Whether a metal bellows seal is required, and whether a sealed cooling jacket or insulation jacket is required.

  • Cooling/insulation method:Whether pump body jacket heating or cooling is required, and the type of heating medium.

  • Drive method:Whether variable frequency speed control is required, whether an explosion-proof motor is required, and speed control requirements.

  • Installation conditions:Installation orientation, piping connection method, available space.

V. Common Misconceptions in High-Temperature Model Selection

Common misconceptionsTypical manifestationsPossible consequences
Ignoring thermal expansion clearanceSelection based on room-temperature clearance, without accounting for high-temperature expansion allowanceGear seizure or excessive clearance-induced leakage at high temperatures prevents the pump from operating normally.
Improper selection of sealsStandard nitrile rubber seals are still used in high-temperature environments.The seal fails within 200 hours, causing medium leakage and environmental pollution.
No preheating before startupDirect start-up in a cold state, medium condensation causes the start-up torque to exceed the standardPump body seizure, gear breakage; 90% of seizure cases originate from this cause.
Excessive rotational speedHigh-temperature operating conditions still run at normal speedIncreased gear wear, with service life dropping sharply from 8,000 hours to 500 hours

VI. GN Instruments High-Temperature Gear Metering Pump Solution

For high-temperature operating conditions,GN Instruments Instrument Co., Ltd.can provide the CXG series of high-temperature gear metering pumps. The main parameters are as follows:

Product SeriesOperating TemperatureCleaning temperatureKey Features
CXG Series High-Temperature Gear Metering PumpUp to 330°CUp to 450°CThe pump body is drilled with heating holes, and the speed ratio of the reducer is increased under high-temperature conditions, allowing for controllable rotational speed.
High-temperature melt pumpUp to 510°CUp to 590°CCPM tool steel or titanium-tantalum alloy, with an outlet pressure of up to 70 MPa

The CXG series high-temperature gear metering pump features a double circular arc sinusoidal tooth profile, where the tooth profile surfaces do not experience relative sliding during engagement, resulting in smooth operation, low noise, and a long service life. Depending on the properties of the medium, a combination of sealing methods such as a fluororubber skeleton oil seal, a graphite packing seal, or a PTFE packing seal can be selected [reference:18]. The drive can be equipped with an optional servo motor, stepper motor, explosion-proof motor, or brushless motor to meet the requirements of different sites.

Based on your fluid name, maximum operating temperature, viscosity, flow rate range, pressure, and sealing requirements, our engineers will recommend a suitable CXG series high-temperature gear metering pump model and configuration solution. For extreme high-temperature conditions exceeding 330°C, a high-temperature melt pump solution can be recommended. If necessary, we can provide prototype testing services to verify metering accuracy and long-term stability under actual high-temperature operating conditions.