Welcome toA clothing company

How can high-viscosity glue be dispensed consistently?

2026-09-28 17:33:41
views
Reading time: about 5 minutes

Q:How can stable and accurate metering be achieved for high-viscosity adhesives (such as epoxy resins, polyurethanes, silicones, hot-melt adhesives, etc.) during continuous or quantitative dispensing?

A:Focus on confirming viscosity, flow rate, pressure, temperature, shear sensitivity, and material compatibility. For volumetric metering, gear flow meters/gear metering pumps can be evaluated; for mass metering, Coriolis mass flow meters can be evaluated. High-viscosity operating conditions often require heating and insulation, pressure stabilization, pulsation prevention, and appropriate inlet pressure. The final model is determined based on the viscosity-flow rate curve.

I. The Four Major Challenges in Measuring High-Viscosity Adhesives

  • High viscosity, poor flowability:The viscosity of adhesives often reaches thousands to hundreds of thousands of cP, making it difficult for ordinary flowmeters to push the fluid through. Additionally, the adhesive is prone to leaving residues and adhering to the walls of the pipeline.

  • Temperature sensitivity:Viscosity changes dramatically with temperature. For every 5°C fluctuation in temperature, the flow rate may deviate by more than 10%. Some adhesives solidify at low temperatures and cure at high temperatures.

  • Prone to curing and clogging:Two-component adhesives begin to cure after mixing, and single-component adhesives will also form a skin when exposed to moisture, making tiny gaps highly susceptible to clogging.

  • Contains fillers and particles:Thermally conductive adhesives and electrically conductive adhesives often contain metal powders and ceramic powders, which are highly abrasive and can accelerate the wear of gears and bearings.

II. Recommended Metering Solutions

For high-viscosity adhesives, give preference toPositive displacement metering solutionThis is because the positive displacement principle is less affected by viscosity under laminar flow conditions, has high repeatability, and is suitable for quantitative glue application.

SolutionTypical EquipmentApplicable viscosityMetering accuracyApplicable Scenarios
Gear metering pump + miniature gear flow meterLow-speed gear pump / Magnetic gear pump + M Series gear flow meter1,000 ~ 100,000 cP±0.5% of readingContinuous quantitative dispensing and potting of single/dual-component adhesives
Oval Gear flow meterOval Gear flow meter1,000 ~ 50,000 cP±0.5% of readingBatch metering and online monitoring of high-viscosity adhesives
Coriolis mass flow meterMiniature Coriolis mass flow meterSuitable for medium- and low-viscosity adhesives±0.1% ~ ±0.2%Two-component mixing ratio, adhesive with large density fluctuations
Screw pump / Plunger pump + Flow meterScrew metering pump / Ceramic plunger pump + Gear flow meterUltra-high viscosity, containing fillers±1%Thermally conductive adhesives, electrically conductive adhesives, adhesives containing particles

Model selection in one sentence:

  • Conventional high-viscosity adhesive →Gear metering pump + miniature gear flow meter(Closed-loop control)

  • Two-component adhesive proportioning →Coriolis mass flow meteror dual-channel gear metering

  • Adhesives containing fillers and abrasives →Screw pump/plunger pump + wear-resistant gear flow meter

  • Monitoring only, no control →Oval Gear flow meter

III. Six Key Measures for Stable Measurement

  1. Constant temperature control:The glue temperature fluctuation is controlled within ±1°C. The pipeline, pump body, and flow meter can all be equipped with a heating jacket or heat tracing tape. Only when the temperature is stable can the viscosity be stable, and only then can the flow rate be stable.

  2. Back pressure control:Maintain a back pressure of 0.1–0.3 MPa at the flow meter outlet to prevent cavitation of the adhesive in the metering chamber and to reduce leakage through the gear clearance.

  3. Pulsation damping:A pulsation damper or accumulator is installed at the outlet of the gear pump and piston pump to control pressure pulsations within ±2%, preventing significant fluctuations in instantaneous flow.

  4. Filtration and venting:A 20–50 μm filter is installed upstream of the pump to prevent particles from jamming the gears. An air vent valve is positioned at the highest point of the pipeline to ensure that the metering chamber is fully filled with adhesive and free of air bubbles.

  5. Closed-loop control:The flow meter provides real-time feedback, and the PLC or metering controller adjusts the pump speed to form a closed loop, which can automatically compensate for changes in viscosity and wear.

  6. Regular calibration and cleaning:The adhesive cures easily and must be thoroughly cleaned after shutdown. It is recommended to calibrate with the actual adhesive every 3–6 months, and for adhesives containing fillers, this interval should be shortened to 1–3 months.

IV. Typical Adhesive Metering Configuration

  • Epoxy resin potting (viscosity 5,000~20,000 cP):Constant temperature material tank → Gear metering pump → M series micro-gear flow meter → Mixing valve → Dispensing head. The flow meter is equipped with a heating jacket, has a back pressure of 0.2 MPa, and features closed-loop control.

  • Polyurethane two-component ratio (A/B adhesive):Two independent gear metering pumps + two micro-gear flowmeters, or one Coriolis mass flow meter to monitor the total flow rate, with a metering accuracy of up to ±1%.

  • Silicone dispensing (viscosity 10,000~100,000 cP):Screw pump delivery + oval gear flow meter metering, combined with a pulse damper, with a dispensing volume repeatability of ±0.5%.

  • Hot melt adhesive spraying (high temperature, high viscosity):Heated gear metering pump + high-temperature gear flow meter (temperature resistance 200°C), with continuous heat insulation and stable back pressure.

V. GN Instruments's High-Viscosity Adhesive Metering Solution

GN Instruments Instrument Co., Ltd.We can provide a complete solution for metering high-viscosity adhesives:

  • M Series Micro Gear Flow Meters:Minimum flow rate of 0.5 mL/min, accuracy of ±0.5% of the reading. Optional heating jacket, Hastelloy, and PEEK materials are available, making it suitable for high-viscosity and corrosive adhesives.

  • Oval Gear flow meter:Suitable for online monitoring of high-viscosity adhesives, with low pressure loss and good repeatability.

  • Miniature Coriolis Mass Flow Meter:Directly measures mass flow for precise proportioning of two-component adhesives, unaffected by changes in density or temperature.

  • Gear metering pump and control system:Low-speed gear pumps, magnetic gear pumps, and screw pumps, combined with closed-loop controllers, achieve stable and continuous glue application.

  • Supporting Services:Operating condition analysis, adhesive liquid calibration, heating and insulation solution design, and prototype testing.

Model Selection Recommendations:Please provide parameters such as the name of the adhesive, viscosity range, temperature, flow rate range, whether it contains fillers, single/dual components, and control precision requirements. Our engineers will configure a suitable metering solution for you.